STP CAT 7 PVC
Product Name/Code:STP Cat 7 PVC
Performance
Application: Frequency RL Attenuation NEXT PSNEXT
100 Base-T4 (MHz) (dB) (dB/100m)    
100 Base-TX min. max min (dB) min (dB)
100VG - AnyLAN 1.000 20.00 2.00 80.00 77.00
1000 Base-T (Gigabit Ethernet) 4.000 23.00 3.60 80.00 77.00
155 Mbps ATM 10.00 25.00 5.70 80.00 77.00
622 Mbps AT 16.00 25.00 7.20 80.00 77.00
Reference Standard 20.00 25.00 8.10 80.00 77.00
EIA/TIA 568B & ISO/IEC 11801 31.25 23.60 10.10 80.00 77.00
Cable Construction
62.50 21.50 14.50 75.50 72.50
Conductor Solid Bare Copper 100.00 20.10 18.50 72.40 69.40
AWG 22/23 200.00 18.00 26.80 67.90 64.90
Conductor Diameter(mm) 0.64/0.574 250.00 17.30 30.20 66.50 63.50
Insulation Solid PE 300.00 17.30 33.30 65.30 63.30
600.00 17.30 48.90 60.80 57.80
Average Thickness (mm) 0.2 Frequency ELFEXT PSELFEXT
ACR
Insulation Diameter(mm) 1.00 (MHz)    
Drain wire Tinned copper min (dB) min (dB)  
Construction (mm) 7/0.2 1.000 80.00 77.00   78.00
Al foil (Individual) Aluminium/PET foil 4.000 80.00 77.00   76.40
    10.00 74.00 71.00   74.30
    16.00 69.90 66.90   72.80
Sheathing PVC /FRPVC 20.00 68.00 65.00   71.90
Thickness(mm) 1.4 31.25 64.10 61.10 69.90
Diameter(mm) 9.1(22 AWG) 62.50 58.10 55.10 61.00
8(23 AWG) 100.00 54.00 51.00 53.90
Core Identificatin/Color Code According to customer request 200.00 48.00 45.00 41.10
Bending Radius 6xOverall Diameter 250.00 46.00 43.00 36.30
    300.00 44.50 41.50 32.00
    600.00 38.40 35.40   11.90
Fire Performance
Electrical Performance
Flame propagation Test to IEC 332 Part 1(PVC)
Flame Propagation Test to IEC 60332 Part 1 and Part 3(FEPVC)
Max.Conductor DC Resistance at 20 ℃(Ω/Km) <93.8
Operating Temperature( ℃ ) 70
Velocity of propagation 79%
Impedance(ohm) 100±15

website: www.caledonian-cables.com

email: sales@caledonian-cables.com